泉州力士樂伺服放大器維修點:F860 Overcurrent: Short in Powerstage過電流:功率級短路。Description:The current in the power transistor bridge has exceeded twice the peak current of the drive. As a result, the drive will be immediately turned off.說明:功率晶體管電橋中的電流已超過驅(qū)動器峰值電流的兩倍。因此,驅(qū)動器將立即關(guān)閉。
The drive has switched to a torque-free condition. An optional brake isimmediately activated.
驅(qū)動器已切換到無扭矩狀態(tài)?蛇x制動器立即啟動。
Cause:原因:
1. Short circuit in the motor cable.
電機電纜短路。
2. Defective power section of the drive controller.
驅(qū)動器控制器的電源部分有缺陷。
3. The current regulator was incorrectly parameterized.
電流調(diào)節(jié)器參數(shù)設(shè)置不正確。
Remedy:解決方法:
1. Check the motor cable for a short.
檢查電機電纜是否短路。
2. Exchange drive controller.
交換驅(qū)動器控制器。
3. The current regulator parameters should not deviate from the default values of the feedback.電流調(diào)節(jié)器參數(shù)不應(yīng)偏離反饋的默認值。