嘉興博世力士樂(lè)控制器維修中心:F860 Overcurrent: Short in Powerstage過(guò)電流:功率級(jí)短路.Description:說(shuō)明:The current in the power transistor bridge has exceeded twice the peak current of the drive. 功率晶體管電橋中的電流已超過(guò)驅(qū)動(dòng)器峰值電流的兩倍。
As a result, the drive will be immediately turned off.
因此,驅(qū)動(dòng)器將立即關(guān)閉。
The drive has switched to a torque-free condition.
驅(qū)動(dòng)器已切換到無(wú)扭矩狀態(tài)。
An optional brake is immediately activated.
可選制動(dòng)器會(huì)立即啟動(dòng)。
Cause:原因:
1. Short circuit in the motor cable.
電機(jī)電纜短路。
2. Defective power section of the drive controller.
驅(qū)動(dòng)器控制器的電源部分有缺陷。
3. The current regulator was incorrectly parameterized.
電流調(diào)節(jié)器參數(shù)設(shè)置不正確。
Remedy:處理措施:
For 1. Check the motor cable for a short.
檢查電機(jī)電纜是否短路。
For 2. Exchange drive controller.
更換驅(qū)動(dòng)器控制器
For 3. The current regulator parameters should not deviate from the default values of the feedback.電流調(diào)節(jié)器參數(shù)不應(yīng)偏離反饋的默認(rèn)值。